Welcome to Shanghai HI RUN system control Co., Ltd!

Contact us Collection site Online Message

National Service Hotline 021-63526338
  • Home
  • About Us
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/about/ —— About Us {/dede:channel}
  • Product Center
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Product Center/ —— Product Center {/dede:channel}
  • News Information
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/News Information/ —— News Information {/dede:channel}
  • Engineering Case
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Engineering Case/ —— Engineering Case {/dede:channel}
  • Sales Outlets
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Sales Outlets/ —— Sales Outlets {/dede:channel}
  • Download
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /Download/ —— Download {/dede:channel}
  • Contact Us
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Contact Us/ —— Contact Us {/dede:channel}
  • Online Message

Hot keyword search:

EN 50382 High Temperature Cabl Location:Home> > English > Product Center > Rolling Stock Cables > EN 50382 High Temperature Cabl >

FIREROL FRL-HT-6SURI 3.6/6 kV - High Temperature Single core cables with Reinforced Insulation

Article source:http://www.trcables.com/   author:上海嗨润   Release time:2018-01-30 13:43   Browse times:second

FIREROL FRL-HT-6SURI
3.6/6 kV - High Temperature Single core cables with Reinforced Insulation

EN 50382 FIREROL FRL-HT-6SURI

Construction

Conductor
extra flexible tinned annealed copper wires(red copper only for 150° C core temperature)class 6 according to HD 383

Insulation
silicon rubber according to EN 50382-1 (EI 112)

Electrical & Mechanical Properties

Nominal Voltage 3.6/6 kV
Maximum Conductor Temperature +120/+150 deg (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 deg (fixed installation)
Bending Radius 3 x Overall Diameter (D<12mm);
  4 x Overall Diameter (D>12mm)

  Chemical & Environmental Properties

EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to mineral oil & fuel oil, acid & alkali
EN 50305 Resistance to ozone

  Fire Performance for rolling stock application

EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

  Fire Performance in general

EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3-24;
NF C 32-070 2.2 (C1); VDE 0472 Teil 804
Vertical flame spread of vertically mounted bunched wires or cables
EN 50268-2; IEC 61034-2; NF C 32-073 ;
NF C 20-902; NF F 16 101; VDE 0472 Teil 816
Low Smoke Emission
EN 50267-2-1; IEC 60754-1; NF C 32-074;NF C 20-454; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; NF C 32-074;NF C 20-453; VDE 0472 Teil 813 Low Corrosivity (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Low Toxicity
NFF 16101; NFF 63808; BS6853 Smoke index

  FRL-HT-6SURI 3.6/6 kV

NOMINAL CROSS-SECTIONAL AREA (a) CONDUCTOR DIAMETER (a) MIN. MEAN THICKNESS OF INSULATION OVERALL DIAMETER WEIGHT RESISTANCE OF CONDUCTOR AT 20°C MIN. INSULATION RESISTANCE
min max TINNED CONDUCTOR PLAIN CONDUCTOR AT +20℃ MIN. AT +150℃MIN.
mm2 mm mm mm mm kg/km Ω/km Ω/km MΩ·km MΩ·km
50 9.2 3.0 15.2 17.8 560 0.393 0.386 340 0.70
70 11.0 3.0 16.9 19.8 770 0.277 0.272 300 0.60
95 12.5 3.0 18.3 21.4 970 0.210 0.206 270 0.55
120 14.2 3.1 20.1 23.5 1200 0.164 0.161 250 0.50
150 15.8 3.1 21.6 25.3 1480 0.132 0.129 220 0.45
185 17.5 3.2 23.4 27.4 1800 0.108 0.106 210 0.40

(a)= For information,indicative only